Riello UPS 2019-12-17T13:17:18+00:00

Project Description

Portfolio » UPS Systems » Riello UPS

Riello UPS

BCL Power supply, install, maintain and support the award winning range of uninterruptible power supply (UPS) systems from Riello UPS. Working with Riello UPS for over 5 years, both the operations and sales teams at BCL Power are well placed to advise on the correct Riello UPS solution for our clients.

With both single and three phase UPS systems in their product range, Riello UPS are able to offer standby power solutions to a variety of end users. From small desktop systems to large data centre applications, the requirement for reliable standby power has never been greater.

BCL Power’s operations team have been trained in the installation and commissioning of the Riello UPS product range, allowing us to provide a single point of call for the purchase, installation and ongoing support of Riello UPS systems.

BCL Power are both an approved reseller and service provider for Riello UPS.

FOUNDED

1922

SPECIALISE IN

Single phase and three phase UPS Systems from 400 VA to 6.4 MVA

Riello UPS Sentinel Pro

Range 700va – 3KVA
Datasheet
User Manual

The Riello SENTINEL PRO is an on-line double-conversion UPS, offering the highest levels of reliability and protection for critical servers, voice and data processing IT systems. The UPS is highly efficient. Riello SENTINEL PRO is designed to save energy and has a power-off push-button feature to reduce energy consumption to zero, when no load is connected or switched off. For long runtime applications, Sentinel Pro (ER models) can be fitted with matching battery extension packs which also include additional battery boost chargers.

The Sentinel Pro delivers proven performance to protecting a wide range of critical servers and IT networks. This tower-style plug and play single-phase UPS is easy to install and use, but incorporates a whole host of sophisticated features.

With a fully microprocessor-controlled inverter, it uses double conversion technology to produce a consistent and reliable output voltage. With a power range of 700-3000 VA, optional more powerful battery chargers are available for the most critical environments requiring extended runtime lasting several hours. In-built battery efficiency testing also ensures optimal performance.

Users can choose from several operating modes to either boost performance or reduce energy consumption:

  • Online Mode: maximum load protection and output voltage quality
  • Eco Mode: maximum efficiency up to 98% as the load is powered by the mains only
  • Smart Active Mode: UPS automatically decides what mode to run depending on the stability of the incoming supply
  • Standby Off Mode: for loads such as emergency lighting, which don’t need power until the mains supply fails
  • Frequency Converter Mode: enables the output frequency to be different to the UPS input frequency

The Sentinel Pro is capable of handling a wide range of input voltages (140 V to 276 V), has a power factor of 0.9, and a high overload capacity of 150%. It incorporates both a Cold Start function, which means the UPS can power up without mains electricity, and an automatic shutdown feature (Eco line) that reduces energy consumption during sustained periods of inactivity.

Thanks to load-based fan speed control, noise levels are limited to less than 40 dBA, minimising any disruption in the working environment.

While the UPS also incorporates a completely revamped LCD display panel clearly showing all vital information, including input and output voltage, remaining battery charge, and the current UPS operating status.

Fully-compatible with the PowerShield3 advanced communications software, which enables the safe shutdown of any equipment connected to the UPS.

  • Designed for critical loads including servers, telecoms networks, and data processing IT systems
  • Range of programmable operating modes (i.e. Eco mode, Smart Active)
  • Available with additional battery boxes to deliver extended runtime
  • Load-based fan speed guarantees low noise levels (40 dBA)

Riello UPS Sentinel Rack (SER)

Range 1.5 – 3KVA
Datasheet
User Manual

The Sentinel Rack is a rack-mounted version of the popular Sentinel Pro range of online uninterruptible power supplies. Advanced double conversion technology provides the highest levels of reliability and protection for critical servers, data processing IT systems, and telecoms networks. Available in 1500 VA and 3000 VA versions, both products sit at just 380mm deep, making them the ideal choice to upgrade power in server rooms housing 600mm deep legacy racks.

FEATURES

• Filtered, stabilised and reliable voltage: double conversion on-line technology (VFI compliant with IEC 62040-3) with filters for the suppression of atmospheric disturbances.
• High overload capability (up to 150%)
• Programmable Auto-restart when mains is restored
• Battery start-up (Cold Start)
• Power factor correction (UPS input power factor, close to 1)
• Wide input voltage tolerance range (from 140 V to 276 V) without battery intervention.
• Runtime extendable up to several hours
• Fully configurable using UPS Tools configuration software
• Highly reliable batteries (automatic and manually-activated battery test)
• High level of UPS reliability (total microprocessor control)
• Low impact on the mains (sinusoidal take up).

ADVANCED COMMUNICATIONS

• Multi-platform communication for all operating systems and network environments: PowerShield3 supervision and shutdown software for Windows operating systems 10, 8, 7, Hyper-V, 2016, 2012, and previous versions, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems
• UPS Tools configuration and customisation software supplied as standard
• RS232 serial port and opto-isolated contacts
• USB port
• Slot for communications boards.

2 YEARS WARRANTY

Riello UPS Sentinel Dual (Low Power)

Range 1 – 3KVA
Datasheet
User Manual

The Riello SENTINEL DUAL (Low Power) is the high density version of the Premium Pro range of double-conversion on-line UPS. Riello SENTINEL DUAL is designed to power critical loads such as servers, storage systems, telephone equipment, medical systems and industrial applications. This Riello UPS can be used as tower UPS or within a rackmount cabinet, and takes up only 2U in height.

The Sentinel Dual (Low Power) is a single-phase uninterruptible power supply offering high performance, efficiency, and versatility.

This advanced dual conversion online UPS protects against mains failures and delivers a stable, filtered power supply to critical loads such as servers, storage systems, VoIP telephone equipment, and medical or industrial equipment. It is designed to deliver high-quality output voltage even when dealing with non-linear loads, making it an ideal solution for high-density blade servers.

Available in 1000-3000 VA versions, this plug and play power supply can be installed in virtually any environment as either a floor-standing tower or rack-mounted in 19-inch cabinets. To change the installation configuration, simply remove and rotate the LCD display panel, rotate the unit by 90o, and either attach or detach the rack supports.

Advanced inverter technologies ensure a 0.9 output power factor and operating efficiency of up to 92%, while components can operate at high temperatures of up to 40oC and load-controlled fans ensure distraction-free noise levels of less than 40 dBA.

Choose from several operating modes that either boost performance or reduce energy consumption:

– Online Mode: maximum load protection and output voltage quality

– Eco Mode: maximum efficiency up to 98% as the load is powered by the mains only

– Smart Active Mode: UPS automatically decides what mode to run depending on the stability of the incoming supply

– Standby Off Mode: for loads such as emergency lighting, which don’t need power until the mains supply fails

– Frequency Converter Mode: enables the output frequency to be different to the UPS input frequency

Batteries are hot-swappable for ease of maintenance, with automatic or manual battery testing available for added reliability. For the most critical scenarios, extended runtime models with additional battery packs or more powerful chargers can be utilised.

The Sentinel Dual (Low Power) also incorporates sophisticated EnergyShare sockets that enable load-shedding so you can prioritise critical loads, along with a simple shut-off button so energy consumption is cut during any periods of prolonged inactivity.

It easily integrates with Riello UPS’s range of advanced communications systems, including PowerShield3 monitoring and shutdown software.

  • Versatile tower or rackmount-style UPS with user-friendly plug and play installation
  • Range of programmable operating modes (i.e. Eco mode, Smart Active)
  • Operating efficiency of up to 92%
  • Available with additional battery boxes to deliver extended runtime

Riello UPS Sentinel Dual (SDU)

Range 4 – 10KVA
Datasheet
User Manual 4KVA
User Manual 5-10KVA

The Riello Sentinel Dual is the best UPS solution for powering mission critical applications and electro-medical devices requiring maximum power reliability.
Flexibility of installation and use (digital display, user-replaceable battery set), as well as the many communication options available, makes the Riello Sentinel Dual suitable for many different applications from IT to security.

Available as either a floor-standing tower or rackmount UPS, the Sentinel Dual SDU offers unity power factor, simple plug and play installation, and a variety of energy-saving modes of operation.

This single-phase online UPS has a power range of 4-10 kVA, with up to three units parallelable to provide either additional capacity or redundancy.

Its capability to handle high-density, non-linear loads makes it an optimum solution for mission-critical server rooms and IT networks, plus electro-medical devices and industrial applications.

As an advanced online dual conversion UPS, the Sentinel Dual SDU not only protects equipment from blackouts and power failures, but it filters and stabilises the mains supply to minimise the risk of other disturbances.

Operational efficiency can reach up to 95%, load-dependent digitally-controlled fans keep the noise levels below 45 dBA, and advanced components are designed to perform even at stress-inducing temperatures of 40oC.

Select between numerous modes of operation that either boost performance or reduce energy consumption:

– Online Mode: maximum load protection and output voltage quality

– Eco Mode: maximum efficiency up to 98% as the load is powered by the mains only

– Smart Active Mode: UPS automatically decides what mode to run depending on the stability of the incoming supply

– Standby Off Mode: for loads such as emergency lighting, which don’t need power until the mains supply fails

– Frequency Converter Mode: enables the output frequency to be different to the UPS input frequency

For the most mission-critical applications, several hours’ extended runtime is achievable either by adding extra battery packs or thanks to chargers with greater power. Overall battery performance is enhanced with both automatic and manual testing, with the batteries themselves hot-swappable and user-replaceable without interrupting the critical load.

Interruption-free maintenance is available using the optional external bypass, while the system is fully-compatible with PowerShield3 communications software, allowing the monitoring and safe shutdown of all connected devices. Equipment can also be prioritised through EnergyShare sockets that enable load-shedding.

  • Versatile tower of rack-mount style UPS with user-friendly plug and play installation
  • Unity power factor
  • Up to 3 SDUs can be operated in parallel
  • Operating efficiency up to 95% (in Online mode)
  • Range of programmable operating modes (i.e. Eco mode, Smart Active)

Riello UPS Sentinel Tower

Range 5 – 10KVA
Datasheet
User Manual

Sentinel Tower is the ideal solution for protecting mission critical systems such as safety devices, telecommunications equipment but also IT systems to ensure maximum power reliability. Sentinel Tower is designed and built using state-of-the-art technology and components to provide maximum protection to the powered loads with no impact on downstream systems and optimised energy savings.

The series includes 5-6 kVA single/singlephase and 8-10 kVA single/three-phase input single-phase output models with on-line double conversion technology (VFI):
the load is powered continuously by the inverter which supplies a sinusoidal voltage, filtered and stabilised in terms of form and frequency. Input and output filters provide significant further immunity from mains disturbances and lightning strikes. In terms of technology and performance, Sentinel Tower is one of the best UPS available on the market today: three level inventer to achieve 95% efficiency, output power factor 1 to increase in efficiency of system and devices and reduce power system losses.

High UPS reliability
• Total microprocessor and DSP control.
• Interruption-free static and manual bypass.
• Specifications guaranteed up to 40°C (the components are designed to work at high temperatures and thus are subject to less stress at normal temperatures).

Parallelable
Parallel configuration of 3 units for (2+1) redundant or power parallel system. The UPS continue to operate in parallel even if the connection cable is interrupted (Closed Loop).

Unity Power Factor
• More power delivered
• More real output power (W)

Operating mode selection
The operating mode can be programmed via software or manually via the front display panel.
• On line: efficiency up to 95%.
• Economy Mode: to increase efficiency (up to to 98%), allows for the selection of Line Interactive technology (VI) to power low priority loads from the mains supply.
• Smart Active: the UPS automatically decides upon the operating mode (VI or VFI) based on the quality of the mains power supply.
• Emergency: the UPS can be selected to function only when the mains power supply fails (emergency only mode).
• Frequency converter operation (50 or 60 Hz).

High quality output voltage
• Even with non-linear loads (IT loads with a crest factor of up to 3:1).
• High short circuit current on bypass.
• High overload capacity: 150% by inverter (even with mains failure).
• Filtered, stabilised and reliable voltage (double conversion on-line technology – VFI compliant with EN62040-3), with filters for the suppression of atmospheric disturbances.
• Power factor correction: UPS input power factor close to 1 and sinusoidal current uptake.

Simplified installation
• UPS can be installed on a single-phase or three-phase distribution network STW 8000 and STW 10000.
• Output terminal board + 2 IEC sockets for powering local consumers (computers, devices, etc.).
• Simplified positioning (built-in castors).

High battery reliability
• Automatic and manual battery test.
• Proper battery care is critical to ensuring correct UPS operation in emergency conditions. The Riello UPS battery care system consists of a series of features and capabilities to optimise battery management and obtain the best performance and operating life possible.
• Unlimited extendible runtime using matching Battery Boxes.
• The batteries do not cut in during mains failures of

Low impact on the mains
Sinusoidal uptake of input current on singlephase/single-phase series.

Runtime expandability
Optional battery extension packs can be connected to increase UPS runtime. In addition the Sentinel Tower range includes ER versions with no internal batteries and more powerful battery chargers for longer runtimes.

Other features
• Advanced diagnostics: status, measurements and alarms available on new custom LCD display.
• Low noise (20 kHz, value above audible range).
• Auto restart (automatic when mains supply is restored, programmable via software.
• Emergency function: the UPS can be selected to function only when the mains power supply fails (emergency lights).
• Back-feed protection standard: to prevent energy from being fed back to the network.
• UPS digital updating (flash upgradeable).

Advanced communications
• Compatible with Riello Connect remote monitoring.
• Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software for Windows operating systems 10, 8, 7, Hyper-V, 2012,2008, and previous versions, Mac OS X, Linux, VMWare ESXi, Citrix XenServer and other Unix operating systems.
• RS232 serial and USB ports.
• Plug and play function.
• Slot for installation of communications boards.

Riello UPS Sentryum

Range 10 – 20KVA
Datasheet

The third generation of Riello UPS transformerless ON LINE UPS systems. The 10-20 kVA Sentryum rewrites the concept of flexible power by offering a choice of three compact cabinet sizes to suit the needs of any small data centre or mission-critical application.

Enhanced overload and short circuit capacity guarantee maximum availability. Incorporating a 5-inch colour touchscreen display and intuitive LED status indicator that automatically changes colour based on the UPS’s current operating state.

The Sentryum (S3T) range is Riello UPS’s third generation of transformerless online uninterruptible power supplies.

Available in 10-15-20 kVA versions, the Sentryum improves on our popular Multi Sentry (MST) series and has been developed following extensive customer feedback.

The S3T redefines the concept of flexible power protection by offering three different cabinet sizes to meet the varied needs of small data centres and mission-critical applications:

Compact (CPT) 

  • Footprint less than 0.25 m2 and volume of 0.17 m3
  • 280mm x 840mm x 700mm (W x D x H)
  • 1 internal battery string
  • Specifically designed for extremely restricted spaces

Active (ACT) 

  • Footprint less than 0.35 m2 and volume of 0.33 m3
  • 380mm x 850mm x 1025mm (W x D x H)
  • 1 or 2 internal battery strings

Xtend (XTD) 

  • Footprint less than 0.4 m2 and volume of 0.5 m3
  • 440mm x 840mm x 1320mm (W x D x H)
  • Up to 3 internal battery strings in a single cabinet
  • Option to add isolation transformer
  • Can upgrade enclosure protection from IP20 or IP21 to IP31

The Sentryum is manufactured used state-of-the-art components designed to run flawlessly at temperatures up to 40 °C. These include a dual-core DSP processor and three-level inverters that operate at high frequency (18 kHz).

This ensures the S3T delivers full-rated power (kVA = kW 1 pf) with exceptional operating efficiency of up to 96.5% in online double conversion mode.

Available as three-phase/single phase input, single-phase output or three-phase input and output, the UPS has a unique control system that reduces harmonic voltage distortion (< 1% at resistive load and < 1.5% at non-linear load).

In addition, the Sentryum has high overload (125% for 10 minutes, 150% for 1 minute) and short circuit (270% for 200ms and 150% for 300ms) capacity, which enables it to handle sudden peak loads without needing to transfer to bypass.

Install up to 8 S3Ts together in parallel to scale capacity or build in redundancy (i.e. N+1 configuration). Closed loop system ensures the UPSs continue to function even if there’s a disruption to the connecting cables.

A revamped 5-inch colour touchscreen display panel clearly highlights crucial UPS measurements and operating statuses. While an innovative new LED status indicator automatically changes its colour (light blue, dark blue, yellow, red) depending on the operating mode and condition of the UPS.

Full range of user-controllable operating modes including:

  • ON LINE
  • ECO (up to 99% efficiency)
  • SMART ACTIVE
  • Emergency (Standby Off)
  • Frequency Converter

The Sentryum range is suitable for use with sealed lead-acid (VRLA), AGM, GEL, open vent or nickel cadmium batteries, as well as alternative backup sources such as supercapacitors and lithium-ion batteries.

It incorporates sophisticated battery management systems, such as deep discharge protection and recharge voltage compensation, to ensure the best performance and operating life. Higher-powered (20 A) battery chargers are available for longer runtime applications.

The S3T incorporates USB, RS232, and RJ10 ports, plus various slots to insert parallel and network communications cards. It is compatible with the full range of Riello UPS networking and UPS management software, including PowerShield3 and PowerNetGuard.

Riello UPS Multi Sentry

Range 10 – 200KVA
Datasheet

Riello MULTI SENTRY is a state-of-the-art uninterruptible power supply,and has been designed to protect critical information and telecommunications systems, networks, services and processes whose operation could be disrupted by poor power quality and/or breaks in their mains power supply. Achieving the highest possible level of on-line double-conversion performance (VFI-SS-111) as defined within IEC EN 62040-3.

The Multi Sentry series delivers exceptional performance and efficiency in one of the most compact footprints in its category, making it the perfect solution for restricted spaces or sites facing commercial pressures to maximise floorspace.

Available in 8 power ranges from 30-200 kVA, it’s suitable for protecting sizeable data centres or smaller communications networks and critical ICT infrastructure.

Thanks to its advanced IGBT rectifier that delivers an input power factor close to one (0.99), the Multi Sentry is well-suited for environments with limited power capacity or issues with harmonics. Compatible with both single-phase and three-phase power sources, this is one of the best UPS on the market for powering capacitive, high-density loads found in blade servers and similar settings.

Capable of operating efficiencies of up to 96.5%, delivering consistent performance with minimal power consumption, users can select from a wide range of UPS operating modes:

– Online Mode: maximum load protection and output voltage quality

– Eco Mode: maximum efficiency up to 98% as the load is powered by the mains only

– Smart Active Mode: UPS automatically decides what mode to run depending on the stability of the incoming supply

– Standby Off Mode: for loads such as emergency lighting, which don’t need power until the mains supply fails

– Frequency Converter Mode: enables the output frequency to be different to the UPS input frequency

For larger installations, up to six Multi Sentry units can be paralleled together in either capacity (N) or redundant (N+) configuration. As it is a closed loop system, protection continues even if the connection cables are interrupted.

In-built wheels offer ease of portability, while the unit also incorporates a range of user-friendly features such as Cold Start – which enables the UPS to power up even without mains supply – and EnergyShare sockets, which allow for load-shedding and the prioritisation of the most critical loads.

Battery reliability is enhanced by a high-frequency charger, which reduces damaging ripple current, and temperature compensation that minimises the risk of overheating. Extended runtimes are available by installing larger battery cabinets.

Easily integrates with Riello UPS’s wide range of advanced communications software such as PowerShield3, which allows for the safe and easy management and shutdown of all connected equipment.

  • Operating efficiency up to 96.5%
  • One of the smallest footprints in its category
  • Compatible with single-phase or three-phase mains supply
  • Suitable for powering capacitive, high-density loads such as blade servers

Riello UPS Multi Power (MPW)

Range 75 – 924KVA
Datasheet

The Riello MULTI POWER (MPW) is designed to protect any critical high-density computer and IT environment, whilst achieving maximum availability. The Riello MPW can grow along with the demands of the business without oversizing the UPS – optimizing both the initial investment and the Total Cost of Ownership. As demand increases, the Riello MPW modular UPS solution can expand its power capability, maintaining the highest levels of power protection, availability, redundancy and investment savings.

Riello Multi Power ensures that a scalable, secure, high quality power supply is available for a variety of critical load applications. The new MPW Power Modules feature the very latest in UPS technology. With its three level Neutral Point Clamped (NPC) inverter and Power Factor Corrected (PFC) input control, the MPW ensures the highest level of performance in terms of overall efficiency, input power factor and harmonic impact on the supply source.

An award-winning modular UPS, the compact yet power-packed Multi Power (MPW) sets new standards in reliability, efficiency, and scalability.

The three-phase power supply in the ultimate choice for mission-critical environments such as data centres and communications networks that require stable and secure high-quality power in a restricted space.

Available in 25 kW or 42 kW versions and installed in cabinets housing several individual power modules, up to four cabinets can be paralleled together to deliver more than 1 MW of total power. For environments where space is particularly restricted, the Multi Power Combo option incorporates power modules and battery units into a single, all-purpose cabinet.

The Multi Power is manufactured using specially-designed, custom-made components, including a three-level Neutral Point Clamped (NPC) inverter that ensures full-rated power. Advanced, transformerless technology also delivers operational efficiency of up to 96.5%, minimising wasted energy. Comparable performance of up to 95% efficiency is even achievable carrying loads as low as just 20%.

Modularity minimises the risk of oversizing the UPS system at initial installation, as it can closely correspond to your load and redundancy requirements. But when it’s time to expand, just add in extra power modules and “pay as you grow”. This reduces the initial financial outlay and spreads the investment over the total cost of ownership (TCO).

Each power module and battery unit making up the Multi Power is hot swappable. This ensures the UPS always remains available, as if there’s ever an issue with one of the modules, the in-built redundancy picks up the slack. This principle extends to downtime-free maintenance too, as any of the modules can be serviced and even replaced without the overall system going offline.

Wasted energy is minimised thanks to three speed-controlled fans inside each power module, which is built with three microprocessors – rather than the usual one – to enhance user communications.

A sizeable 7 inch LCD touchscreen control panel enables user-friendly communication, while the UPS is fully-compatible with Riello UPS’s range of network communications software such as PowerShield3, which allows for monitoring and shutdown of all connected devices.

  • Operating efficiency up to 96.5%
  • Exceptional efficiency even at loads as low as 20%
  • “Pay as you grow” scalability by adding in extra power modules
  • High power density in a compact footprint (466 KW per m²)
  • Hot swappable modules guarantee redundancy and downtime-free maintenance

Riello UPS Master MPS

Range 10 – 800KVA
Datasheet

The Master MPS series of UPS offer maximum power for mission-critical environments such as data centres, telecoms networks, security systems, electro-medical devices, and industrial applications.

Online double conversion UPS technology protects against power failures and eliminates mains disruptions like harmonics, making it a proven choice for systems powered by generators or MV/LV transformers. Easily installed in a wide range of configurations and architectures, with up to 8 units capable of operating in parallel for additional capacity or redundancy.

The Master MPS uninterruptible power supply is a proven performer in almost any mission-critical environment and can handle capacitive loads such as blade servers too. A popular choice in data centres, telecommunications and IT networks, electro-medical devices, and heavy industry, this online, dual conversion UPS is available as both a three-phase input, three-phase output or three-phase input, single-phase output model.

With a power range of 10-800 kVA, up to 8 Master MPS can be paralleled together for additional capacity or redundancy. User-friendly Hot System Expansion (HSE) enables extra UPS to join an existing system without the need to turn off the power or transfer to bypass.

Systems can be configured in a variety of ways to ensure availability and redundancy, including:

– UPS Group Synchroniser (UGS): enables 2 or more non-parallel UPS devices to remain synchronised even during mains power failure. UGS also enables a Riello UPS to synchronise with another independent power source, even one with a different power rating.

– Parallel Systems Joiner (PSJ): this connects 2 groups of UPS in parallel using a power coupling switch. If one of the UPS in the group fails, it is automatically excluded and the PSJ links the remaining UPS to the other group through an external bypass.

The Master MPS only needs a small installation footprint, for example a 200 kVA system requires just 0.64m2. The tower-style units have a removable front panel allowing for easy servicing and maintenance, while because the fans ventilate upwards, it eliminates any requirement for side or rear entry. This means units can be installed up against the wall or back-to-back to save space.

Battery reliability is enhanced by a dedicated battery care system. This incorporates comprehensive testing functionality, a temperature compensation feature, and dual level recharging to optimise recharge currents.

Compatible with Riello UPS’s extensive range of advanced communications and monitoring software such as PowerShield3, which enables the safe shutdown of all connected devices.

  • Up to 8 Master MPS can be installed in parallel for extra capacity or redundancy
  • Hot System Expansion (HSE) add UPS into an existing system with the need to transfer to bypass
  • Available as either three-phase input and output or three-phase input, single-phase output
  • Efficiency Control System (ECS) optimises efficiency based on the power required by the load
  • Delivers quality power in mission-critical environments like data centres, telecoms networks, security systems, electro-medical devices, and industrial applications

Riello UPS Master Industrial

Range 30 – 80KVA
Datasheet

The Master Industrial series is designed to handle the challenging conditions such as vibrations, mechanical stresses, and dust that pose problems to a standard UPS system.

A tower-style, three-phase uninterruptible power supply available in 30-80 kVA power range, it is ideal for industrial applications such as manufacturing and petrochemical processes, power plants, and electrical distribution. Offering double conversion online UPS protection, it is capable of up to 94% efficiency.

Designed to overcome the challenges such as dust, vibration, and mechanical stresses that would cause a standard UPS to buckle, the Master Industrial range delivers reliable protection in even the harshest, most demanding setting.

A three-phase, tower-style dual conversion online UPS, it is available in 30 VA, 40 VA, 60 VA, and 80 VA versions, and can achieve operational efficiency up to 94%.

With a high short-circuit current that makes it an excellent choice for loads requiring high current peaks, it is made for heavy industrial applications, for example, manufacturing processes, electrical power distribution, or power plants.

Batteries deliver a consistent 220 Vdc voltage, the industrial norm, with sophisticated battery care system ensuring enhanced performance and resilience.

Redundant ventilation at 100% load is standard, while each fan is individually monitored and alarmed to highlight any issues.

Fully-compatible with the range of advanced network communications software such as PowerNetGuard and PowerShield3 provided by Riello UPS.

  • Operational efficiency up to 94%
  • Capable of handling harsh industrial environments where vibrations, dust, and mechanical stresses are common
  • Suitable for industrial applications such as manufacturing and petrochemical processes, power plants, and electrical distribution
  • High short-circuit current makes it suitable for loads that need high current peaks
  • Redundant ventilation at 100% load as standard

Riello UPS Master HE

Range 100 – 800KVA
Datasheet

The Master HE uninterruptible power supply series combines exceptional reliability with operational efficiency of up to 95.5%, reducing operators’ power consumption and energy waste.

Available in 10 power ratings from 100-800 kVA, this three-phase online UPS uses advanced double conversion technology to protect mission-critical and industrial loads in settings such as data centres, security systems, electro-medical devices, and telecoms networks.
Delivering unity power factor, it incorporates an output isolation transformer to enhance load protection, while its high-performing components can withstand the stresses of temperatures up to 40oC.

Delivering outstanding performance at lower operating costs, the Master HE range of super-efficient UPS systems is the perfect option for protecting mission-critical and industrial loads.

With a power range of 100-800 kVA, up to 8 units can be installed in parallel to increase capacity or redundancy depending on the requirements.

Using advanced online double conversion technologies, the Master HE is designed to protect data centres, IT and telecommunications networks, electro-medical devices, security systems, and industrial loads from blackouts and other damaging power disturbances.

Its IGBT-based rectifier produces far greater operational efficiency compared against the more conventional thyristor-based systems. In online mode, operational efficiency of 95.5% stands comparison with transformerless UPS power supplies.

Providing a unity power factor, it includes an output isolation transformer which offers better load protection, enables the UPS to be supplied from two independent lines, and guarantees higher immunity to any harmonics generated by the load.

Users can manually select or programme a variety of operating modes that improve system performance or efficiency:

  • Online Mode: maximum load protection and output voltage quality
  • Eco Mode: maximum efficiency up to 99% as the load is powered by the mains only
  • Smart Active Mode: UPS automatically decides what mode to run depending on the stability of the incoming supply
  • Standby Off Mode: for loads such as emergency lighting, which don’t need power until the mains supply fails
  • Frequency Converter Mode: enables the output frequency to be different to the UPS input frequency

Delivering high power in a compact footprint, for example, a 250 kVA model can be installed in 0.85m2 space, the Master HE can be configured in a variety of ways, such as:

  • UPS Group Synchroniser (UGS): enables 2 or more non-parallel UPS devices to remain synchronised even during mains power failure. UGS also enables a Riello UPS to synchronise with another independent power source, even one with a different power rating.
  • Parallel Systems Joiner (PSJ): this connects 2 groups of UPS in parallel using a power coupling switch. If one of the UPS in the group fails, it is automatically excluded and the PSJ links the remaining UPS to the other group through an external bypass.

Quick maintenance and service access is available thanks to a removable front panel, which also incorporates an advanced LCD display panel showcasing UPS status and alarms, input and output voltage, battery levels, and other measurements that can be used to monitor performance and calculate data centre power usage effectiveness (PUE).

Integrates with Riello UPS’s full suite of monitoring and networking communications software such as PowerNetGuard and PowerShield3.

  • Operational efficiency up to 95.5%
  • Up to 8 Master HE can be installed in parallel for extra capacity or redundancy
  • Delivers quality power in mission-critical environments like data centres, telecoms networks, security systems, electro-medical devices, and industrial applications

PowerShield³ provides efficient, userfriendly UPS management, displaying all major operational information such as input voltage, applied load and battery charge. The software also provides detailed information on fault conditions and UPS operating states. Developed with a client/server architecture, it is the ideal tool for managing multi-platform network systems.

  • PowerShield³ FULL version: supports up to maximum of 32 UPS for all operating systems.
  • With sequential and priority-based shutdown, PowerShield³ provides unattended shut-down of all networked PCs, saving any active work on the most widely used applications. Users can definethe shutdown priorities for the various computers in the network and can also customise the procedure.
  • With multi-platform compatibility, PowerShield³ uses the TCP/IP communications protocol to achieve standardised management and monitoring across the widest possible range of platforms. This makes it possible to monitor computers with different operating systems from a single console, for example monitoring a UNIX server from a PC running Windows and also connecting to UPS located in different geographical areas using dedicated networks (intranets) or the Internet.
  • With event scheduling, PowerShield³ users can program their own shutdown procedures, detailing power-off and power-up scenarios to increase system security and save energy.
  • With messages management, PowerShield3 keeps users constantly informed about the status of UPS and environmental sensors, either locally or via network messages. A list can also be defined of users who should receive e-mails, faxes, voice messages and SMS messages when faults or sudden mains power supply failures occur.
  • Integrated SNMP agent: PowerShield³ features an integrated SNMP agent for UPS management which can send all the information required and generate traps using the RFC1628 standard, and environmental sensors.
  • Secure, easy to use and connect; communication is now password protected to ensure UPS system security. Using the new discovery/ browsing function, all UPS connected to a protected computer and/or LAN can be displayed in a list format for monitoring. In the absence of a LAN connection, support is provided for modem-based communication.

Developed for virtualized systems
PowerShield³ permits to initiate live migration of virtual machines (VM) to automatically and transparently migrate VMs during power disturbance to protected devices by UPS with migration systems
such as VMware vMotion™ and Microsoft Live Migration. PowerShield3 can monitor and manage UPS either inside or outside the data centre. Can also measure power consumption to help calculate power usage effectiveness (PUE), a the standard metric utilized for gauging data centre power efficiency.

Security, easy to use and connect, communication is password protected to ensure UPS system security. Using the new discovery/browsing function, all the RIELLO UPS connected to a protected computer or LAN can be displayed in a list format. In the absence of a LAN connection, support is provided for modembased communication.

Riello UPS PowerNetGuard

Datasheet

PowerNETGuard software centralises UPS management using network interface (SNMP) communications. It is ideal for Data Centre managers and medium to large sized networks. PowerNETGuard uses the RFC1628 standard Management Information Base (MIB) and ensures standardised UPS management wherever they are located.

  • Centralised control of remote UPS via Ethernet with SNMP protocol
  • Multi-level display of geographical areas, building plans, maps, etc.
  • Multi-user access with various security levels
  • Compatible with NetMan and RFC 1628 standard SNMP agents
  • Creation of graphs of input and output values and data back-up to file
  • Alarm notifications via e-mail and SMS
  • Integrated Wap Server for alarm display
  • For Windows operating systems (2008 Server, Vista, 2003 and XP), Linux, Solaris 8, 9 and 10.

The NetMan 204 network agent allows UPS directly connected over LAN 10/100 Mb connections to be managed using the main network communication protocols (TCP /IP , HTTP HTTPS, SSH, SNMPv1, SNMPv2 and SNMPv3). It is the ideal solution for the integration of UPS over Ethernet networks with Modbus/TCP and BACnet/IP protocols. It was developed to integrate UPS into medium-sized and large networks, to provide a high level of reliability in communication between the UPS and associated management systems.

New features include the LDAP and Active Directory user authentication and the full integration with VMware’s Esxi and vCenter server for VM and host graceful shutdown.

  • 32bit RISC processor
  • Compatible with 10/100 Mbps Ethernet and IP v4/6 networks
  • Compatible with PowerShield³ and TeleNetGuard
  • Web User Interface for Configuration, Management, and Administration.
  • Seamlessly integrates with VMware’s Esxi and vCenter server
  • LDAP and Active Directory user authentication
  • SNMP v1, v2 and v3 with Standard IETF UPS MIB (RFC 1628) and Riello UPS Mib for PowerNetGuard and NMS connections
  • SNMP v1 with RFC3433 for the management of environmental sensors
  • HTTP and HTTPS for UPS control via web browser
  • SMTP for alarm notifications and UPS status updates via email
  • Modbus/TCP
  • BACnet/IP
  • Maximum expandability
  • WiFi ready, using a customized dongle can communicate via WiFi network
  • Events log and data management
  • Wake-on-LAN management for starting computers via TCP /IP network
  • Other standards: DHCP, DNS, FTP, NTP , ICMP , IGMP
  • Management of environmental sensors
  • Configurable via SSH sessions and HTTP
  • Firmware upgradeable via FTP and HTTP

Riello UPS Environmental Sensors

Datasheet
User Manual

The Netman environmental sensors monitor and record environmental conditions as well as activities in protected areas and at the premises where the UPS is installed. The environmental sensors allow extensive control and management of the environment around the UPS by monitoring the temperature, humidity, triggering devices such as fans or locks and communicating the values via web, SNMP and via the PowerShield³ software.

  • The following sensors are available:
    • -55 +125 °C Temperature Sensor
    • -55 +125 °C Temperature and 0-100% humidity Sensor
    • -55 +125 °C Temperature and I/O digital 0-12 Vdc In, 1A max Out at 48 Vdc Sensor
  • Firmware upgradeable via FTP and HTTP